Transformer 230V to 24V - Lancer 75VA Resetting for International Beverage

Ask a question Item # 25-0048/02-SP In stock

Transformer 230V to 24V - Lancer 75VA Resetting for International Beverage

In stock
$3035
30-day returns · Easy with prepaid labels provided
Special order ships in 1–2 weeks
Contact us for in stock options.
  • Input: 230V 50/60Hz
  • Output: 24V 75VA
  • Reset: Self-resetting (auto-recovery from fault)
  • Application: International (European/Asian) market Lancer beverage equipment
  • Manufacturer: Lancer
  • SKU / MPN: 25-0048/02-SP

View full details →

Get PRO Pricing
3% back · Net 30 terms & More
Apply for HowdyPro →
?
Need a hand?
Bilingual support from real techs · Mon–Fri 8:30–5 CT
(888) 964-4239 Chat with a tech

Request a quote

Need a custom build, freight order, or just want pricing in writing before you order? Quotes back within 24 hours.

Request a quote

The Lancer 230V 24V Transformer is the electrical cornerstone for international dispensers, converting 230V line power into the safe 24V current required for logic boards and solenoids. It features an integrated 75VA manual reset circuit breaker to protect the unit's electronics from downstream electrical shorts.

Problem Solved: Restores power distribution to internal electronics and dispensing valves. Eliminates 'Dead Machine' conditions caused by line surges or component failures.

Symptoms of Failure: Total loss of display and valve activation while line power is present, a humming transformer housing, or the transformer tripping immediately upon power-up.

Technician’s Note: If the 75VA breaker trips, check the agitating motor and all valve solenoids for shorts before resetting. A transformer that fails repeatedly is usually a symptom of a grounded component elsewhere in the system.
Technical Specifications:
  • Primary Voltage: 230V / 50-60Hz
  • Secondary Voltage: 24V AC
  • Capacity: 75VA (Volt-Amps)
  • Protection: Integrated Manual Reset