Get it by 3–5 business days
Free shipping · Change ZIP
As soon as tomorrow. Choose Next Day during checkout.
- Official Lancer OEM precision part.
- Restores factory-standard performance.
- Heavy-duty commercial service rating.
- SKU: 82-4226-SP
?
Need a hand?
Bilingual support from real techs · Mon–Fri 8:30–5 CT
Request a quote
Need a custom build, freight order, or just want pricing in writing before you order? Quotes back within 24 hours.
The Lancer 32VDC Solenoid Assembly Short Link for IBD is the electromagnetic actuator responsible for lifting the valve plunger to initiate the pour of syrup or water.
Problem Solved: Restores reliable valve actuation and ensures a crisp, immediate shut-off at the end of the dispensing cycle.
Symptoms of Failure: A 'dead' dispensing station where nothing happens when the lever is pressed, or a chattering noise from the valve head indicating a weak coil.
Technician’s Note: Check for sticky syrup residue in the solenoid guide tube. Syrup buildup causes the armature to bind, which is the most frequent cause of coil burnout.
Technical Specifications:- Manufacturer: Lancer
- MPN / SKU: 82-4226-SP
- Specification: 32VDC
- Compatibility: Designed for Genuine Lancer Dispensing Units