- MaintainsServing Temp for Remote Runs.
- 24 lb Ice Bank thermal battery.
- 4-circuit high-efficiency cooling.
- Removable refrigeration deck.
Request a quote
Need a custom build, freight order, or just want pricing in writing before you order? Quotes back within 24 hours.
The Lancer 115V 24 lb 604 Delta Line Chiller is a heavy-duty remote cooling unit designed to keep syrup and water lines at serving temperature between the back-room pumps and the dispensing tower. It builds a 24 lb ice bank in an internal water bath, providing the thermal mass required to handle high-volume serving periods without temperature spikes.
Symptoms of Failure: If drinks at the tower are coming out warm or foam-heavy, the chiller has likely failed to build an ice bank. This is often caused by a seized agitator motor or a refrigeration leak. A 'frozen' water bath (ice bridging) is another common symptom, which prevents the product coils from making proper thermal contact with the cold water.
- Voltage: 115V / 60Hz
- Ice Bank Capacity: 24 lbs
- Circuit Count: 4 Independent Product Circuits
- Refrigerant: R290 Eco-Friendly
- Application: Remote Beverage Chilling