Glycol Beer Chiller - UBC ChillPro 7500 Power Pack, 3/4 HP 1-Pump 7,500 BTU Commercial Long-Draw Draft

Glycol Beer Chiller - UBC ChillPro 7500 Power Pack, 3/4 HP 1-Pump 7,500 BTU Commercial Long-Draw Draft
- 7,500 BTU/h cooling capacity at a 20°F evaporator temperature, using R290 refrigerant.
- One vane pump installed (1/3 hp motor, 80 GPH); UBC lists one additional pump.
- 208-230 V, 60 Hz, NEMA 6-20P plug, 20 A dedicated circuit; 10.0 A running with one pump.
- 18-gallon glycol tank with 3/8 in. barbed inlet and outlet.
- Needs 12 in. of clearance on all sides and a 60 to 90°F room.
Request a quote
Need a custom build, freight order, or just want pricing in writing before you order? Quotes back within 24 hours.
This power pack puts a single vane pump on a 7,500 BTU/h chiller. UBC's specification sheet lists one pump pre-installed and one additional.
The UBC ChillPro 7500 circulates chilled glycol through the trunk line, where it travels beside the beer lines and then returns to the bath. Draft systems with a remote keg cooler rely on that loop to stop beer warming up on its way to the faucet. This listing is the one-pump version of the ChillPro 7500. The same chiller is also made with two pumps installed, so check the pump count before you order.
Features
- One vane pump installed, driven by a 1/3 hp motor and moving 80 GPH of glycol.
- UBC's specification sheet lists one additional pump.
- 7,500 BTU/h of cooling capacity at a 20°F evaporator temperature.
- 18-gallon glycol tank, so there is a large volume of cold glycol behind the pump.
- Digital thermostat controls the bath temperature.
- Uses R290 refrigerant, with a 150 g (5.29 oz) charge, per UBC's specification sheet.
- 3/8 in. barbed inlet and outlet for the glycol supply and return lines.
Specifications
| Cooling capacity | 7,500 BTU/h at 20°F evaporator temperature |
|---|---|
| Pumps installed | 1 vane pump with 1/3 hp motor |
| Additional pumps | 1 |
| Pump flow | 80 GPH |
| Glycol tank | 18 gallons |
| Maximum tubing distance | Up to 450 ft |
| Electrical | 208-230 V, 60 Hz |
| Dedicated circuit | 20 A |
| Running amperage | 10.0 A with one pump |
| Plug and cord | NEMA 6-20P, 6 ft cord |
| Refrigerant | R290 |
| Glycol connections | 3/8 in. barb inlet and outlet |
| Dimensions (W x D x H) | 28 x 23 x 30.5 in. (35.6 in. on legs) |
| Operating room temperature | 60 to 90°F |
| Clearance | 12 in. around the entire unit |
| Glycol mix | 40% glycol, 60% water by volume |
Compatibility
Plan the electrical first. The ChillPro 7500 needs a 208-230 V, 60 Hz supply on a 20 A dedicated circuit, with a receptacle that takes its NEMA 6-20P plug. The cord is 6 ft long. Leave at least 12 in. clear on every side and keep the room between 60 and 90°F. UBC specifies a bath of 40% glycol and 60% water by volume. Unsure whether one pump is enough for your layout? Talk to a specialist before you order.
Documents & Downloads
More from UBC Group
Shop all UBC Group →Recently viewed
Searches related to this
Frequently asked questions
Can a second glycol pump be added to the one-pump ChillPro 7500 later?
UBC's specification sheet for the ChillPro 7500 lists one pre-installed pump and one additional pump. Each vane pump has a 1/3 hp motor and moves 80 GPH.
What outlet and circuit does the ChillPro 7500 need?
It runs on 208-230 V, 60 Hz and has a NEMA 6-20P plug on a 6 ft cord. UBC lists a 20 A dedicated circuit.
What are the dimensions of the chiller?
The cabinet is 28 in. wide and 23 in. deep. Height is 30.5 in., or 35.6 in. on its legs.
At what conditions is the 7,500 BTU/h rating given?
UBC states the 7,500 BTU/h capacity at an evaporator temperature of 20°F.
What size are the glycol line connections?
The glycol inlet and outlet are 3/8 in. barbs.